Skip to main content
Version: Version 3.3 - Segmentation Support 🚧

URL

You can modify the URL at any state of the app to get the desired result. Here are different part of the APP that you can modify:

WorkList​

The WorkList can be modified by adding the following query parameters:

PatientName​

The patient name can be modified by adding the PatientName query parameter.

/?patientName=myQuery

MRN​

The MRN can be modified by adding the MRN query parameter.

/?mrn=myQuery

Description​

The description can be modified by adding the Description query parameter.

/?description=myQuery

Modality​

The modality can be modified by adding the modalities query parameter.

/?modalities=MG

Accession Number​

The accession number can be modified by adding the accession query parameter.

/?accession=myQuery

DataSources​

If you happen to have multiple data sources configured, you can filter the WorkList by adding the dataSources query parameter.

/?dataSourcename=orthanc
tip

You can add sortBy and sortDirection query parameters to sort the WorkList

/?patientName=myquery&sortBy=studyDate&sortDirection=ascending

Viewer​

The Viewer can be modified by adding the following query parameters:

Mode​

As you have seen before, the Viewer can be configured to be in different modes. Each mode registers their id in the URL.

For instance

/viewer?StudyInstanceUIDs=1.3.6.1.4.1.14519.5.2.1.7009.2403.871108593056125491804754960339

will open the viewer in the basic (longitudinal) mode with the StudyInstanceUID 1.3.6.1.4.1.14519.5.2.1.7009.2403.871108593056125491804754960339.

And if configured, the same study can be opened in the tmtv mode

/tmtv?StudyInstanceUIDs=1.3.6.1.4.1.14519.5.2.1.7009.2403.871108593056125491804754960339

StudyInstanceUIDs​

You can open more than one study in the Viewer by adding the StudyInstanceUIDs

/viewer?StudyInstanceUIDs=1.3.6.1.4.1.25403.345050719074.3824.20170125095722.1&StudyInstanceUIDs=1.3.6.1.4.1.25403.345050719074.3824.20170125095258.1
tip

You can ues this feature to open a current and prior study in the Viewer. Read more in the Hanging Protocol Module section

SeriesInstanceUIDs​

Sometimes you need to only open a specific series in a study, you can do that by

/viewer?StudyInstanceUIDs=1.3.6.1.4.1.25403.345050719074.3824.20170125095722.1&SeriesInstanceUID=1.3.6.1.4.1.25403.345050719074.3824.20170125095748.1

This will only open the viewer with one series (one displaySet).